Batteryless current clamps?

Ask a question - edaboard.com

elektroda.net NewsGroups Forum Index - Electronics Equipment - Batteryless current clamps?

Goto page Previous  1, 2, 3, 4

daestrom
Guest

Fri Nov 20, 2009 4:53 pm   



Tzortzakakis Dimitrios wrote:
Quote:
? "John Larkin" <jjlarkin_at_highNOTlandTHIStechnologyPART.com> ?????? ???
?????? news:dnsag51jfmub8nppj2kfj3nt07l3jv6djg_at_4ax.com...
On Thu, 19 Nov 2009 07:29:26 -0800, Fester Bestertester <fbt_at_fbt.net
wrote:

So, for a millivolt output probe, this might be as simple as 2 windings
(or a
tapped single winding) with a range switch to select the winding?
Current transformers are usually dumped into a load resistor aka
burden resistor, to convert their output current into voltage. I'm
sure the Fluke clamp-on has an internal burden resistor, and they may
switch that to change ranges.

Without a burden resistor, the output voltage will be proportional to
frequency and very dependent on core reluctance, which would be fatal
for a clamp-on meter with a hinge and a non-repeatable air gap.

Coreless Rogowsky coils are used unloaded, but need a downstream
integrator to accurately measure current.

http://en.wikipedia.org/wiki/Rogowski_coil

The coolest current transformer is a second-harmonic DCCT, accurate to
parts-per-million from DC to many kilohertz.

http://www.gmw.com/electric_current/Danfysik/866_867/867.html
Anyway, current transformers must always be operated with the secondary
shorted. In the generating facilities in Kozani, West Macedonia, where 400
kV current transformers were involved, the operators of the plant had a
special indicator whether the secondary was shorted.


Some old switchboard CT's I worked on in the Navy had very thin
insulator between two spring clips. Whenever we wanted to remove a
meter for cal, we slip the insulator out so the two clips would short
together, shorting the CT. Then we could open circuit the meter and
remove it from the panel. I don't remember exactly what the blade was
made of, but it's surface wasn't perfectly smooth like polished
material, more porous like unglazed ceramic (of course it wasn't any metal).

The reason they built the insulator so thin was that if one accidentally
open-circuited the CT without removing the wafer first, the high voltage
developed by the CT would just 'punch thru' the wafer and safely short
the CT. Then all you had to do to repair things was make sure you
closed the circuit and replace the wafer-thin insulator blade.

Was kind of surprised when I moved to commercial power systems that they
didn't use something similar. Just has to have a breakdown voltage that
is low enough to avoid damaging the CT.

daestrom

John Larkin
Guest

Fri Nov 20, 2009 5:44 pm   



On Fri, 20 Nov 2009 10:53:45 -0500, daestrom <daestrom_at_twcny.rr.com>
wrote:

Quote:
Tzortzakakis Dimitrios wrote:
? "John Larkin" <jjlarkin_at_highNOTlandTHIStechnologyPART.com> ?????? ???
?????? news:dnsag51jfmub8nppj2kfj3nt07l3jv6djg_at_4ax.com...
On Thu, 19 Nov 2009 07:29:26 -0800, Fester Bestertester <fbt_at_fbt.net
wrote:

So, for a millivolt output probe, this might be as simple as 2 windings
(or a
tapped single winding) with a range switch to select the winding?
Current transformers are usually dumped into a load resistor aka
burden resistor, to convert their output current into voltage. I'm
sure the Fluke clamp-on has an internal burden resistor, and they may
switch that to change ranges.

Without a burden resistor, the output voltage will be proportional to
frequency and very dependent on core reluctance, which would be fatal
for a clamp-on meter with a hinge and a non-repeatable air gap.

Coreless Rogowsky coils are used unloaded, but need a downstream
integrator to accurately measure current.

http://en.wikipedia.org/wiki/Rogowski_coil

The coolest current transformer is a second-harmonic DCCT, accurate to
parts-per-million from DC to many kilohertz.

http://www.gmw.com/electric_current/Danfysik/866_867/867.html
Anyway, current transformers must always be operated with the secondary
shorted. In the generating facilities in Kozani, West Macedonia, where 400
kV current transformers were involved, the operators of the plant had a
special indicator whether the secondary was shorted.


Some old switchboard CT's I worked on in the Navy had very thin
insulator between two spring clips. Whenever we wanted to remove a
meter for cal, we slip the insulator out so the two clips would short
together, shorting the CT. Then we could open circuit the meter and
remove it from the panel. I don't remember exactly what the blade was
made of, but it's surface wasn't perfectly smooth like polished
material, more porous like unglazed ceramic (of course it wasn't any metal).

The reason they built the insulator so thin was that if one accidentally
open-circuited the CT without removing the wafer first, the high voltage
developed by the CT would just 'punch thru' the wafer and safely short
the CT. Then all you had to do to repair things was make sure you
closed the circuit and replace the wafer-thin insulator blade.

Was kind of surprised when I moved to commercial power systems that they
didn't use something similar. Just has to have a breakdown voltage that
is low enough to avoid damaging the CT.

daestrom

Lower-power CT, like residential-metering size, 100 amps or so, will
generally tolerate being unloaded. They will saturate and make two
not-too-huge voltage spikes per cycle and not get very warm. The nasty
part is that, once the burden is reconnected, they are very likely to
wind up magnetized, which will mess up low-current accuracy.

John

JosephKK
Guest

Fri Nov 20, 2009 6:00 pm   



On Tue, 17 Nov 2009 07:20:32 -0800 (PST), Tim Williams
<tmoranwms_at_gmail.com> wrote:

Quote:
On Nov 17, 2:18 am, Fester Bestertester <f...@fbt.net> wrote:
I'm curious how the Fluke i200s current clamp probe can give mV output
without the use of batteries.

Is that the one with the 10/100 switch and a green LED?

I'm pretty sure most of the weight is not ferrite, it's a battery
somewhere.

Actually about equally ferrite and plastic with copper coming at about
1/3 either of those. No battery whatsoever and AC only.
Quote:

They also read DC, and have an offset knob to account for the
ferrite's hysteresis.

Only active probes do that.
Quote:

The passive probes only read AC, and as I recall, are 1 or 10 mV/A.

Tim

I can make any output ratio i want, i know how they work.

Bill Sloman
Guest

Fri Nov 20, 2009 8:43 pm   



On Nov 20, 1:31 pm, John Fields <jfie...@austininstruments.com> wrote:
Quote:
On Thu, 19 Nov 2009 10:43:58 -0800 (PST),Bill Sloman





bill.slo...@ieee.org> wrote:
On Nov 19, 3:18 pm, John Fields <jfie...@austininstruments.com> wrote:
On Wed, 18 Nov 2009 15:08:46 -0800 (PST),Bill Sloman

bill.slo...@ieee.org> wrote:
On Nov 18, 8:45 pm, John Fields <jfie...@austininstruments.com> wrote:
On Wed, 18 Nov 2009 08:46:00 -0800 (PST),Bill Sloman

bill.slo...@ieee.org> wrote:
On Nov 17, 9:28 pm, John Fields <jfie...@austininstruments.com> wrote:
On Tue, 17 Nov 2009 10:59:38 -0800, "Joel Koltner"

zapwireDASHgro...@yahoo.com> wrote:
"John Fields" <jfie...@austininstruments.com> wrote in message
news:sir5g5h9h69vfurapjd9e2kn8efeod8qat_at_4ax.com...
news:7ar5g59hdrcdpu3icb3rlmdn31iqiqfa67_at_4ax.com

5uA... nice!

Seems that someone on eBay is selling a +/-5uA movement:
http://cgi.ebay.com/Weston-Bakelite-Glass-5ua-microamp-Panel-Meter-Hi...

Nope, it'll get you nothing. Smile
Know why?

Because the federales will toss your rear in jail quite rapidly?

---
Nope, because the magnetic field generated by the power line will never
cut the conductor wrapped around it since the conductor will be
essentially perpendicular to the varying field. :-)

Since the original claim was

" >Wrapping some turns around the power company's lines will get you
many, many
watts. Smile"

This isn't the reason - lines is plural and the nett current through
the lines as a bunch balances out to zero.

---
Since that's obvious to the most casual observer, the context of his
statement must have been about wrapping some turns around [one] of the
power company's lines, which I addressed by referring to it as "the
power line".
---

Nice try.

snipped the rest

---
Of course, you fraud, since by snipping the rest you sidestep the issue,
which is your ignorance in believing that a solenoid wound around an
alternating current carrying conductor can be used to extract power from
the varying magnetic field surrounding that conductor.

Your enthusiasm for inventing implausible straw men knows no bounds. I
never made any such claim. My scepticism about you claim was purely
based on the fact that you were ignoring what Joel Koltner had
actually said.

---
What Joel _actually_ said was that energy could be extracted from the
varying magnetic field surrounding a power line by wrapping turns around
it.

Since you pointed out that energy can't be had by wrapping turns around
bundled conductors carrying charge flowing in opposite directions,
that's something that, obviously, every dunce realizes.

Knowing that, my take on Koltner's lighthearted comment was that he was
referring to a single conductor, such as the ones used in high voltage
distribution systems which are called, by the way, "power lines".

Wrapping turns around a high voltage power line probably wouldn't be a
good idea.

<snip>

--
Bill Sloman, Nijmegen

John Fields
Guest

Sat Nov 21, 2009 1:38 am   



On Fri, 20 Nov 2009 10:43:14 -0800 (PST), Bill Sloman
<bill.sloman_at_ieee.org> wrote:

Quote:
On Nov 20, 1:31 pm, John Fields <jfie...@austininstruments.com> wrote:

What Joel _actually_ said was that energy could be extracted from the
varying magnetic field surrounding a power line by wrapping turns around
it.

Since you pointed out that energy can't be had by wrapping turns around
bundled conductors carrying charge flowing in opposite directions,
that's something that, obviously, every dunce realizes.

Knowing that, my take on Koltner's lighthearted comment was that he was
referring to a single conductor, such as the ones used in high voltage
distribution systems which are called, by the way, "power lines".

Wrapping turns around a high voltage power line probably wouldn't be a
good idea.

---
So, then, you agree that, aside from the obvious danger of wrapping
turns around a high voltage line, no appreciable power can be drawn from
the line by a coaxial solenoid surrounding the line?

JF

JosephKK
Guest

Sat Nov 21, 2009 1:29 pm   



On Fri, 20 Nov 2009 08:44:19 -0800, John Larkin
<jjlarkin_at_highNOTlandTHIStechnologyPART.com> wrote:

Quote:
On Fri, 20 Nov 2009 10:53:45 -0500, daestrom <daestrom_at_twcny.rr.com
wrote:

Tzortzakakis Dimitrios wrote:
? "John Larkin" <jjlarkin_at_highNOTlandTHIStechnologyPART.com> ?????? ???
?????? news:dnsag51jfmub8nppj2kfj3nt07l3jv6djg_at_4ax.com...
On Thu, 19 Nov 2009 07:29:26 -0800, Fester Bestertester <fbt_at_fbt.net
wrote:

So, for a millivolt output probe, this might be as simple as 2 windings
(or a
tapped single winding) with a range switch to select the winding?
Current transformers are usually dumped into a load resistor aka
burden resistor, to convert their output current into voltage. I'm
sure the Fluke clamp-on has an internal burden resistor, and they may
switch that to change ranges.

Without a burden resistor, the output voltage will be proportional to
frequency and very dependent on core reluctance, which would be fatal
for a clamp-on meter with a hinge and a non-repeatable air gap.

Coreless Rogowsky coils are used unloaded, but need a downstream
integrator to accurately measure current.

http://en.wikipedia.org/wiki/Rogowski_coil

The coolest current transformer is a second-harmonic DCCT, accurate to
parts-per-million from DC to many kilohertz.

http://www.gmw.com/electric_current/Danfysik/866_867/867.html
Anyway, current transformers must always be operated with the secondary
shorted. In the generating facilities in Kozani, West Macedonia, where 400
kV current transformers were involved, the operators of the plant had a
special indicator whether the secondary was shorted.


Some old switchboard CT's I worked on in the Navy had very thin
insulator between two spring clips. Whenever we wanted to remove a
meter for cal, we slip the insulator out so the two clips would short
together, shorting the CT. Then we could open circuit the meter and
remove it from the panel. I don't remember exactly what the blade was
made of, but it's surface wasn't perfectly smooth like polished
material, more porous like unglazed ceramic (of course it wasn't any metal).

The reason they built the insulator so thin was that if one accidentally
open-circuited the CT without removing the wafer first, the high voltage
developed by the CT would just 'punch thru' the wafer and safely short
the CT. Then all you had to do to repair things was make sure you
closed the circuit and replace the wafer-thin insulator blade.

Was kind of surprised when I moved to commercial power systems that they
didn't use something similar. Just has to have a breakdown voltage that
is low enough to avoid damaging the CT.

daestrom

Lower-power CT, like residential-metering size, 100 amps or so, will
generally tolerate being unloaded. They will saturate and make two
not-too-huge voltage spikes per cycle and not get very warm. The nasty
part is that, once the burden is reconnected, they are very likely to
wind up magnetized, which will mess up low-current accuracy.

John

There is no CT in residential metering, the energy meter is connected
directly. Even commercial / light industrial you do not see CTs in
the meter circuit until 600 A, and before that you are typically at
480 V 3-phase (in the US).

John Larkin
Guest

Sat Nov 21, 2009 4:42 pm   



On Sat, 21 Nov 2009 04:29:36 -0800,
"JosephKK"<quiettechblue_at_yahoo.com> wrote:

Quote:
On Fri, 20 Nov 2009 08:44:19 -0800, John Larkin
jjlarkin_at_highNOTlandTHIStechnologyPART.com> wrote:

On Fri, 20 Nov 2009 10:53:45 -0500, daestrom <daestrom_at_twcny.rr.com
wrote:

Tzortzakakis Dimitrios wrote:
? "John Larkin" <jjlarkin_at_highNOTlandTHIStechnologyPART.com> ?????? ???
?????? news:dnsag51jfmub8nppj2kfj3nt07l3jv6djg_at_4ax.com...
On Thu, 19 Nov 2009 07:29:26 -0800, Fester Bestertester <fbt_at_fbt.net
wrote:

So, for a millivolt output probe, this might be as simple as 2 windings
(or a
tapped single winding) with a range switch to select the winding?
Current transformers are usually dumped into a load resistor aka
burden resistor, to convert their output current into voltage. I'm
sure the Fluke clamp-on has an internal burden resistor, and they may
switch that to change ranges.

Without a burden resistor, the output voltage will be proportional to
frequency and very dependent on core reluctance, which would be fatal
for a clamp-on meter with a hinge and a non-repeatable air gap.

Coreless Rogowsky coils are used unloaded, but need a downstream
integrator to accurately measure current.

http://en.wikipedia.org/wiki/Rogowski_coil

The coolest current transformer is a second-harmonic DCCT, accurate to
parts-per-million from DC to many kilohertz.

http://www.gmw.com/electric_current/Danfysik/866_867/867.html
Anyway, current transformers must always be operated with the secondary
shorted. In the generating facilities in Kozani, West Macedonia, where 400
kV current transformers were involved, the operators of the plant had a
special indicator whether the secondary was shorted.


Some old switchboard CT's I worked on in the Navy had very thin
insulator between two spring clips. Whenever we wanted to remove a
meter for cal, we slip the insulator out so the two clips would short
together, shorting the CT. Then we could open circuit the meter and
remove it from the panel. I don't remember exactly what the blade was
made of, but it's surface wasn't perfectly smooth like polished
material, more porous like unglazed ceramic (of course it wasn't any metal).

The reason they built the insulator so thin was that if one accidentally
open-circuited the CT without removing the wafer first, the high voltage
developed by the CT would just 'punch thru' the wafer and safely short
the CT. Then all you had to do to repair things was make sure you
closed the circuit and replace the wafer-thin insulator blade.

Was kind of surprised when I moved to commercial power systems that they
didn't use something similar. Just has to have a breakdown voltage that
is low enough to avoid damaging the CT.

daestrom

Lower-power CT, like residential-metering size, 100 amps or so, will
generally tolerate being unloaded. They will saturate and make two
not-too-huge voltage spikes per cycle and not get very warm. The nasty
part is that, once the burden is reconnected, they are very likely to
wind up magnetized, which will mess up low-current accuracy.

John

There is no CT in residential metering, the energy meter is connected
directly. Even commercial / light industrial you do not see CTs in
the meter circuit until 600 A, and before that you are typically at
480 V 3-phase (in the US).

Of course there is. I delivered over 1800 electronic submetering units
for the Battery Park City apartment complex, and, trust me, we used
CTs. Lots of electronic meters use CTs. You should get out more.

John

James Sweet
Guest

Sat Nov 21, 2009 9:37 pm   



Quote:

There is no CT in residential metering, the energy meter is connected
directly. Even commercial / light industrial you do not see CTs in
the meter circuit until 600 A, and before that you are typically at
480 V 3-phase (in the US).


My uncle's house (in the US) has a 400A service with current
transformers. They're not common but they do exist. IIRC 200A is the
largest residential meter.

John Larkin
Guest

Sat Nov 21, 2009 10:03 pm   



On Sat, 21 Nov 2009 12:37:10 -0800, James Sweet
<jamesrsweet_at_gmail.com> wrote:

Quote:


There is no CT in residential metering, the energy meter is connected
directly. Even commercial / light industrial you do not see CTs in
the meter circuit until 600 A, and before that you are typically at
480 V 3-phase (in the US).


My uncle's house (in the US) has a 400A service with current
transformers. They're not common but they do exist. IIRC 200A is the
largest residential meter.

It's dangerous to make catagorical statements like "There is no CT in
residential metering." It only takes one counter-case to make you
wrong.

John

Michael A. Terrell
Guest

Sun Nov 22, 2009 12:58 am   



John Larkin wrote:
Quote:

On Sat, 21 Nov 2009 12:37:10 -0800, James Sweet
jamesrsweet_at_gmail.com> wrote:



There is no CT in residential metering, the energy meter is connected
directly. Even commercial / light industrial you do not see CTs in
the meter circuit until 600 A, and before that you are typically at
480 V 3-phase (in the US).


My uncle's house (in the US) has a 400A service with current
transformers. They're not common but they do exist. IIRC 200A is the
largest residential meter.

It's dangerous to make catagorical statements like "There is no CT in
residential metering." It only takes one counter-case to make you
wrong.


Like the claim that no US homes have three phase power that was made
on this group (alt.engineering.electrical) a few years ago.


--
The movie 'Deliverance' isn't a documentary!

John Fields
Guest

Sun Nov 22, 2009 1:55 am   



On Fri, 20 Nov 2009 10:43:14 -0800 (PST), Bill Sloman
<bill.sloman_at_ieee.org> wrote:

Quote:
On Nov 20, 1:31 pm, John Fields <jfie...@austininstruments.com> wrote:

Knowing that, my take on Koltner's lighthearted comment was that he was
referring to a single conductor, such as the ones used in high voltage
distribution systems which are called, by the way, "power lines".

Wrapping turns around a high voltage power line probably wouldn't be a
good idea.

---
He said, with his last breath, and then quietly sank into the sea...

JF

Goto page Previous  1, 2, 3, 4

elektroda.net NewsGroups Forum Index - Electronics Equipment - Batteryless current clamps?

Ask a question - edaboard.com

Arabic version Bulgarian version Catalan version Czech version Danish version German version Greek version English version Spanish version Finnish version French version Hindi version Croatian version Indonesian version Italian version Hebrew version Japanese version Korean version Lithuanian version Latvian version Dutch version Norwegian version Polish version Portuguese version Romanian version Russian version Slovak version Slovenian version Serbian version Swedish version Tagalog version Ukrainian version Vietnamese version Chinese version Turkish version